UV dose calculator

Pick the material and the lamp, set power and belt speed. The calculator checks the dose against the datasheet window and tells you which speed or power lands in the middle of it.

TDS window
2500 - 3500 mJ / cm² (UVA)
Band
UVA
Film thickness
For a usual film thickness of 200 ± 50µm
Exposure
UV is invisible: the beam colour is a convention (365 nm deep violet, 405 nm blue-violet). Drag on the stage to change the belt speed.UV is invisible: the beam colour is a convention. Each change runs one pass of the lamp over the board: inside the TDS window the coating cures; below it, it stays glossy, bluish and tacky, as in Hoenle’s lab test on PT 4600.
05,808 mJ/cm²

5,280 mJ/cm²

Above the window: overdose

TDS window: 2,500–3,500 mJ/cm²

For the middle of the window (3,000 mJ/cm²): belt at 4.4 m/min at this power, or 57 % power at this speed.

  • The TDS names only the band (UVA), no wavelength. The LED’s suitability is confirmed in a trial.
Assumptions
  • Dose scales linearly with power; Hoenle does not state this.
  • Catalogue irradiance is Hoenle’s typical value, Hoenle: “measured with Hoenle LED sensors for UV meter” (Hoenle states no measuring distance).
  • Working distance enters only through the measured value above; distance curves come from Hoenle (v2).
  • Time under the lamp = window length along the belt ÷ belt speed. Length along the belt: window as printed: “82 x 20 or 122 x 20” mm; Short side of the window, i.e. the lamp mounted across the belt. Hoenle does not state the mounting orientation; this is a Naltek assumption printed under the result.
Sources
  • PT 4600: 2500 - 3500 mJ / cm² (UVA) [ELANTAS Bectron® PT 4600 TDS, p. 3]
  • Hoenle LED Powerline ACIC – ACIC 820 XP, 82 × 20 mm: 365 nm column of the typical-intensity row “11.000 16.000 16.000 22.000” (mW/cm²) [Hoenle AG flyer, LED Powerline ACIC, p. 2]
  • Length along the belt: window as printed: “82 x 20 or 122 x 20” mm; Short side of the window, i.e. the lamp mounted across the belt. Hoenle does not state the mounting orientation; this is a Naltek assumption printed under the result. [Hoenle AG flyer, LED Powerline ACIC, p. 2]
  • Power: between 10 % and 100 % in 1 %-steps. [Hoenle AG flyer, LED Powerline ACIC, p. 2]
  • PT 4600: blue → green/yellow [ELANTAS Bectron® PT 4600 TDS, p. 2]

Want the dose measured on your line? Write to us