Hoenle AG LED UV curing systems

We offer Hoenle AG UV curing systems in Romania. The 18 LED systems on this page run from hand-held pens to line arrays, conveyors and chambers. They emit UV at 365, 385, 395 or 405 nm, or visible light at 460 nm. The figures are Hoenle’s, from its product flyers (updated 09/25); each entry links to its flyer.

Hoenle LED Powerline Focus switched on, built into a machine
Hoenle LED Powerline Focus switched on, built into a machine. Image: Hoenle AG

Hand-held

3
Hoenle LED Pen 2.0

LED Pen 2.0

Simple hand-held UV-LED curing pen for manual workstations and R&D labs.

Wavelengths
365 nm
Intensity (Hoenle)
4800 mW/cm² at aperture; 650 mW/cm² at 5 mm (Hoenle UV Meter, LED sensor)

Hoenle product flyer (PDF)

Hoenle LED Power Pen 2.0

LED Power Pen 2.0

Hand-held UV-LED curing pen with focusing lens system for small areas and very short cycle times.

Wavelengths
365 or 405 nm, one per pen
Intensity (Hoenle)
10,000 mW/cm² @365 nm; 16,000 mW/cm² @405 nm (12 mm distance) (Hoenle UV Meter, LED sensor)

Hoenle product flyer (PDF)

Hoenle UVAHAND LED

UVAHAND LED

Portable hand-held UV-LED lamp for curing adhesives over larger areas and fluorescence inspection; plugs straight into mains.

Wavelengths
365 or 405 nm (Hoenle)
Intensity (Hoenle)
365 nm unit: 200 mW/cm²; 405 nm unit: 350 mW/cm² (at 20 mm)

Hoenle product flyer (PDF)

Spot

1
Hoenle bluepoint LED

bluepoint LED

Stackable UV-LED spot curing system with detachable touch display; up to 4 LED heads per unit, up to 20 heads per display.

Wavelengths
365 / 385 / 405 nm
Intensity (Hoenle)
up to 20,000 mW/cm² at 385/405 nm and 14,000 at 365 nm with Optic 3 at 10 mm working distance (Hoenle UV Meter, LED light-guide sensor L2); larger optics give less (Optic 20: 1,450–1,850 at 40 mm)

Hoenle product flyer (PDF)

Area

4
Hoenle LED Spot W

LED Spot W

Compact water-cooled UV-LED flood unit with a 20 × 20 mm exit window.

Wavelengths
365 / 385 / 395 / 405 / 460 nm
Intensity (Hoenle)
365: 14,000 | 385: 16,000 | 395: 25,000 | 405: 25,000 | 460: 30,000 mW/cm² (typical; Hoenle LED sensors for the UV Meter; Hoenle states no distance)

Hoenle product flyer (PDF)

Hoenle LED Spot 40 IC

LED Spot 40 IC

Compact air-cooled UV-LED flood unit (40 x 40 mm) with integrated controller for tight spaces.

Wavelengths
365 / 385 / 395 / 405 / 460 nm
Intensity (Hoenle)
365: 3,000 | 385: 7,000 | 395: 7,000 | 405: 7,000 | 460: 10,000 mW/cm² (typical, 0 mm)

Hoenle product flyer (PDF)

Hoenle LED Spot 100 IC / HP IC

LED Spot 100 IC / HP IC

Mid-size air-cooled UV-LED flood unit (100 x 100 mm), standard and high-power versions, gap-free tiling.

Wavelengths
365 / 385 / 395 / 405 / 460 nm
Intensity (Hoenle)
HP IC: 2200/3000/3500/4000/5000 mW/cm²; IC: 1100/1500/1700/2000/2500 mW/cm² (365/385/395/405/460 nm) (typical; Hoenle UV Meter, LED surface sensor (VIS sensor at 460 nm), distance 0 mm)

Hoenle product flyer (PDF)

Hoenle LED Spot 200 HP IC

LED Spot 200 HP IC

Large high-intensity air-cooled UV-LED flood unit (200 x 50 mm), modular for larger areas.

Wavelengths
365 / 385 / 395 / 405 / 460 nm
Intensity (Hoenle)
2,200/3,000/3,500/4,000/5,000 mW/cm² (365/385/395/405/460 nm, HP version) (typical; Hoenle LED-F3 surface sensor, VIS-F1 at 460 nm; Hoenle states no distance)

Hoenle product flyer (PDF)

Line

3
Hoenle LED Powerline ACIC (with LED Powerdrive IC)

LED Powerline ACIC (with LED Powerdrive IC)

Air-cooled high-intensity UV-LED line array, stackable, for integration into conveyors, indexing and rotary tables.

Wavelengths
365 / 385 / 395 / 405 nm
Intensity (Hoenle)
ACIC 820 XP: 365: 11,000 | 385: 16,000 | 395: 16,000 | 405: 22,000 mW/cm² (typical, measured with Hoenle LED sensor; distance not stated; 385/395/405 nm maximum on the 122 mm version needs a special cable and one module per LED Powerdrive 1200 IC); ACIC 410: 365: 2,000 | 385/395/405: 4,000 mW/cm²

Hoenle product flyer (PDF)

Hoenle LED Powerline LC (with LED Powerdrive)

LED Powerline LC (with LED Powerdrive)

Water-cooled UV-LED line array; lengths up to 3,000 mm on request; clean-room suitable.

Wavelengths
365 / 385 / 395 / 405 nm
Intensity (Hoenle)
365: 14,000 | 385: 20,000 | 395: 25,000 | 405: 25,000 mW/cm² (typical; Hoenle LED sensors for the UV Meter; Hoenle states no distance)

Hoenle product flyer (PDF)

Hoenle LED Line 500

LED Line 500

Portable 500 mm UV-LED line light with built-in driver and timer; stackable to any length.

Wavelengths
365 or 405 nm (Hoenle)
Intensity (Hoenle)
365: 130 mW/cm²; 405: 300 mW/cm² (20 mm distance)

Hoenle product flyer (PDF)

Conveyor

1
Hoenle Convey LED

Convey LED

Table-top UV conveyor carrying LED Powerline ACIC, LED Spot 100 IC / HP IC, LED Powerline LC or JetCure LED heads, up to 25 W/cm², tunnel height up to 50 mm.

Wavelengths
365 / 385 / 395 / 405 / 460 nm

Hoenle product flyer (PDF)

Chamber

2
Hoenle LED Cube 100 IC

LED Cube 100 IC

Compact UV-LED irradiation chamber (approx. 180 mm cube usable space) for lab or manual production, door-interlocked.

Wavelengths
365 / 385 / 395 / 405 / 460 nm
Intensity (Hoenle)
with LED Spot 100 HP IC: 2,200 / 3,000 / 3,500 / 4,000 / 5,000; with LED Spot 100 IC: 1,100 / 1,500 / 1,700 / 2,000 / 2,500 mW/cm² (365/385/395/405/460 nm, 0 mm)

Hoenle product flyer (PDF)

Hoenle LED Cube 350 IC

LED Cube 350 IC

UV-LED irradiation chamber with 350 x 350 mm footprint for larger parts, lab or manual production.

Wavelengths
365 / 385 / 395 / 405 / 460 nm
Intensity (Hoenle)
2,200/3,000/3,500/4,000/5,000 mW/cm² (with LED Spot 200 HP IC; 365/385/395/405/460 nm; Hoenle LED area sensor (VIS at 460 nm), distance 0 mm)

Hoenle product flyer (PDF)

Print drying

4
Hoenle LED Powerline Web

LED Powerline Web

Water-cooled COB LED-UV curing system for narrow-web label and flexible-packaging presses (retrofit or new).

Wavelengths
385 / 395 nm
Intensity (Hoenle)
up to 34,000 mW/cm² at the window (34 W/cm²); max. electrical power 90 W/cm

Hoenle product flyer (PDF)

Hoenle LED Powerline LC HV

LED Powerline LC HV

Water-cooled UV-LED array for intermediate and final curing in printing, 400 V DC supply.

Wavelengths
365 / 385 / 395 / 405 nm
Intensity (Hoenle)
20 mm version: 365: 12,000 | 385/395/405: 25,000 mW/cm²; 40 mm version: 365: 8,000 | 385/395/405: 16,000 mW/cm² (Hoenle UV Meter with LED sensor; Hoenle states no distance)

Hoenle product flyer (PDF)

Hoenle JetCure LED

JetCure LED

Air-cooled modular UV-LED array (41 mm grid) for printing pinning/final curing, in S (side exhaust) and T (top exhaust) versions.

Wavelengths
365 / 385 / 395 / 405 nm
Intensity (Hoenle)
20 mm version: 365: 10,000 | 385/395/405: 20,000 mW/cm²; 40 mm version: 365: 6,000 | 385/395/405: 16,000 mW/cm² (Hoenle LED sensors for the UV Meter; Hoenle states no distance)

Hoenle product flyer (PDF)

Measuring the dose: Hoenle UV Meter and UV Disc Integrator

Hoenle UV Meter with its sensors Hoenle UV Scan reader with macsStrips dose strips

The Hoenle UV Meter measures both broad-spectrum UV and LED systems. Its LED surface sensor covers 265–485 nm, and it comes with a PTB-traceable certificate. It is the instrument behind Hoenle’s own LED figures.

The UV Disc Integrator rides on the conveyor belt and shows the dose in mJ/cm², from 1 to 999,999 mJ/cm² at ± 5 %. Its LED intensity range is 1–10,000 mW/cm², so close to the window of an ACIC 820 XP at 365 nm the UV Meter is the instrument to use.

Readings from different meters are not directly comparable. When you compare a measured value with a Hoenle figure, note which meter and sensor you used.

Source: Hoenle AG, hoenle.com and the UV Meter flyer.

How to pick the unit: dose = intensity × time

The coating’s datasheet sets the dose. The lamp’s intensity and the time under it deliver it. Bectron® PT 4600 asks for 2,500–3,500 mJ/cm² UVA. Hoenle states a typical 11,000 mW/cm² at 365 nm for the LED Powerline ACIC 820 XP. If its 20 mm window runs along the belt, a board spends 0.48 s under it at 2.5 m/min, and we calculate about 5,300 mJ/cm².

This is a calculation. Hoenle states no measuring distance for its figure, and mounting the 20 mm side along the belt is our assumption. Working distance and wavelength match lower the dose at the board; a trial on your line confirms whether an LED unit suits the coating. ELANTAS developed PT 4600 for broad UVA curing; LED can work as well. On request we measure the dose on your line during a visit.

Run your own lamp, coating and belt speed in the UV dose calculator, or read the guide to UV dose on a conveyor.

Buying Hoenle AG systems through Naltek

Lead time
Standard units, accessories and spare parts: about 4–5 weeks from order. Custom systems: per quote.
Delivery
We agree the delivery terms with you for each order.
Certification
DIN EN ISO 9001 and DIN EN ISO 14001 belong to Hoenle AG (Hoenle product flyers).

See also: UV curing · Tacky UV coating · Line problems

Ask for a sample, a TDS, a quote or a dose calculation

Tell us what you need. We reply within 24 hours, in Romanian or English.

What do you need?

The button opens your email program with the inquiry filled in; you send it from there. We use these details only to answer this inquiry. Privacy notice

Contact directly

Alexandru Nichifor
Sales & technical support

+40 771 709 622

nichiforlx@nalteksolutions.com

Naltek Solutions S.R.L.
Sat Comori, Com. Gurghiu, nr. 81, jud. Mureș 547298