Technical guides
Each guide starts from a problem on the line and answers it with datasheet values, with the source next to every number.
31 October 2026
Bectron® printed-electronics inks discontinued: VFP silver, carbon and dielectric alternatives
ELANTAS ended the Bectron printed-electronics ink line in Sep 2026. VFP silver, carbon and dielectric inks: cure, mesh and resistivity from VFP data.
Printed electronics
18 October 2026
Conformal coating vs potting for power electronics: what the datasheets show
In Bectron TDSs the thick-film coating PK 4340 lists 0.22–0.28 W/m·K; the potting compounds PU 4527, SK 75V2-45 and PU 4526 list 0.54 to 0.70 W/m·K.
Conformal coating · Potting and encapsulation · Thermal management
PU 4526 · PU 4515 · PU 4527 · SK 75V2-45 · PK 4340 · PK 4342 · PT 4600 · PL 4122-40 · MR 3406
18 October 2026
Hot-melt (melting resin) PCB coating: what application temperature?
The ELANTAS TDS for Bectron MR 3406 asks for 190–200 °C at the nozzle and a reservoir at 170 °C for 1 day maximum; 180 °C is the viscosity reference.
Melting resins (hot melt)
MR 3406 · MR 3406 FR · MR 3404
18 October 2026
How to protect a PCB from condensation: coating options with datasheet values
Condensation needs a coating that stays insulating when wet. Bectron TDS values after water immersion: PL 4122-40 E, PT 4600, PK 4340, MR 3406.
Conformal coating
PL 4122-40 · PT 4600 · PK 4340 · MR 3406
18 October 2026
Silicone vs polyurethane potting: temperature, cure and moisture from the TDS
Bectron SK 75V2-45 silicone potting is rated −55 to +200 °C; the polyurethanes PU 4515 and PU 4526 stop at +150 °C and +130 °C (ELANTAS TDS).
Potting and encapsulation
SK 75V2-45 · SK 75V2-65 · PU 4515 · PU 4526 · PU 4527
18 October 2026
Thin-film vs thick-film conformal coating: solvent, cure and film build compared
PL 4122-40 E thin film: 40 % solids, about 80 mPa·s, 16 h cure at 23 °C. PT 4600 thick film: solvent-free, 200 ± 50 µm, UV-cured in about 5 s (TDS).
Conformal coating
PL 4122-40 · PL 4122-45 · PT 4600 · PK 4340 · MR 3406 · AC 93 · 217 · 239 · 300
18 October 2026
Why a UV-cured conformal coating stays tacky
Tacky UV coating usually means too little UVA dose or shadow areas still moisture-curing. PT 4600 TDS: 2,500–3,500 mJ/cm² UVA, 2–3 days shadow cure.
Conformal coating · UV curing
PT 4600 · PT 4601
18 October 2026
How to calculate UV dose on a conveyor: mW/cm², mJ/cm² and belt speed
Dose (mJ/cm²) = irradiance (mW/cm²) × exposure time (s); time = lit length ÷ belt speed. Worked example for a 3000 mJ/cm² UV coating.
UV curing
PT 4600 · PT 4601
Ask for a sample, a TDS, a quote or a dose calculation
Tell us what you need. We reply within 24 hours, in Romanian or English.
Contact directly
Alexandru Nichifor
Sales & technical support
nichiforlx@
Naltek Solutions S.R.L.
Sat Comori, Com. Gurghiu, nr. 81, jud. Mureș 547298